Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code PC 03: High or low pressure protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code PC 03 on a heat pump means: High or low pressure protection. It is also called Viessmann diagnostic code PC 03.

High severityHeat PumpVitocal IND-O

Homeowner? What Viessmann code PC 03 means for you

Call a technician Your heat pump is reporting: High or low pressure protection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PC 03 mean?

Operation lamp flashes 7 times, timer lamp flashing. The refrigerant system pressure is outside the protected range.

Applies to: DLFSOAH09XAK, DLFSOAH18XAK outdoor units

Common causes of Viessmann code PC 03

  • High refrigerant pressure
  • Low refrigerant pressure
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
PC 00IPM malfunction or IGBT over-strong current protection
PC00IPM malfunction or IGBT over-strong current protection
PC 01Over-voltage or low-voltage protection
PC01Overvoltage or low voltage protection
PC 02Compressor top temperature or IPM high temperature protection
PC02Compressor top temperature or IPM high temperature / high pressure protection
PC03Low pressure protection
PC 04Inverter compressor drive error
PC04Inverter compressor drive error
PC 06Discharge temperature protection of compressor
PC06Discharge temperature protection of compressor
PC08Current overload protection

All Viessmann Heat Pump error codes →

Viessmann code PC 03: homeowner questions

What does Viessmann code PC 03 mean?

High or low pressure protection. Operation lamp flashes 7 times, timer lamp flashing. The refrigerant system pressure is outside the protected range.

Is it safe to keep using my heat pump with code PC 03?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code PC 03 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PC 03 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PC 03 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSOAH service manual, PDF p. 15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service