Viessmann Heat Pump: Compressor winding resistance check
Compressor winding resistance check on a Viessmann heat pump: Checks the compressor windings for balance when a compressor or IPM fault is suspected.
Applies to: Compressor, PC00 fault
How to fix compressor winding resistance check: step by step
- Disconnect the compressor.
- Measure resistance between U-V, V-W and U-W.
- All three values should be equal.
- If they are not equal, the compressor is faulty and must be replaced.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Source: DLFSHC Service Manual, p. 29. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.