Viessmann Error Code EC 72: Missing phase failure of outdoor DC fan motor (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EC 72 on a heat pump means: Missing phase failure of outdoor DC fan motor. It is also called Viessmann diagnostic code EC 72.

High severityHeat PumpVitocal 100-S · DLCURA

Homeowner? What Viessmann code EC 72 means for you

Call a technician Your heat pump is reporting: Missing phase failure of outdoor DC fan motor. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EC 72 mean?

The three-phase sampling current of the DC fan motor is abnormal. One or more phases stay very low, close to 0.

Applies to: DLCURA outdoor units, models 18AAK to 60ABK

Common causes of Viessmann code EC 72

  • Open circuit in fan motor three-phase output
  • Loose or bad fan motor wiring
  • Unequal or open fan motor windings

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code EC 72

Show all 22 models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other Viessmann Heat Pump codes

CodeMeaning
EC 55IGBT temperature sensor TH open or shorted
EC55Open or short circuit of temperature sensor (outdoor)
EC 56Evaporator coil outlet temperature sensor T2B open or shorted
EC56Open or short circuit of temperature sensor (outdoor)
EC57Refrigerant pipe temperature sensor error
EC71Overcurrent failure of outdoor DC fan motor
EC72Lack phase failure of outdoor DC fan motor
EC73Zero-speed failure of outdoor DC fan motor
EH(xx)Indoor unit error code EH(xx)
EH 0bCommunication error between display board and main board
EH 0EWater-level alarm malfunction
EH0EWater-level alarm malfunction

All Viessmann Heat Pump error codes →

Viessmann code EC 72: homeowner questions

What does Viessmann code EC 72 mean?

Missing phase failure of outdoor DC fan motor. The three-phase sampling current of the DC fan motor is abnormal. One or more phases stay very low, close to 0.

Is it safe to keep using my heat pump with code EC 72?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code EC 72 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EC 72 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EC 72 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-S DLCURA service manual, PDF p. 47. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.