Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Heat Pump: DHW tank and DHW piping requirements

Updated · by Aurora Star Tech Inc.

DHW tank and DHW piping requirements on a Viessmann heat pump: A non-Viessmann DHW tank requires the installer to verify the tank temperature sensor with the tank maker. A tempering valve is strongly recommended in the DHW supply line. DHW piping must be at least the size of the Vitocal DHW connections so the integral pump has enough residual head.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocal 100-AW AM2V domestic hot water

How to fix dhw tank and dhw piping requirements: step by step

  1. For a non-Viessmann tank, verify the DHW tank temperature sensor operation with the tank manufacturer.
  2. Install a temperature tempering valve in the DHW supply line.
  3. Size DHW supply and return piping to at least the Vitocal DHW outlet size.
  4. For non-Viessmann tanks, calculate the tank coil pressure drop against the integral pump residual head.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

More commissioning tips for heat pump

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 46. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977