Viessmann Heat Pump: Thermostat terminal use on the terminal strip
Thermostat terminal use on the terminal strip on a Viessmann heat pump: Y2 is used for optional stage 2 heating or cooling. On a single speed system nothing is wired to the B terminal. E is used for an optional strip heater; leave it unwired if there is no strip heat or aux heat.
Applies to: Terminal strip wiring
How to fix thermostat terminal use on the terminal strip: step by step
- Wire stage 2 heat/cool to Y2 if the system has it.
- Leave B unwired on single speed systems.
- Wire strip heat to E only if the system has strip or aux heat.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
Source: Vitocal 100-WA technical data manual, p. 12. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.