Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Heat Pump: IPM continuity check

Updated · by Aurora Star Tech Inc.

IPM continuity check on a Viessmann heat pump: Procedure to check the IPM module continuity on the outdoor unit when an IPM-related fault (PC00) is present.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Outdoor IPM module, PC00 fault

How to fix ipm continuity check: step by step

  1. Turn off the outdoor unit and disconnect the power supply.
  2. Discharge the electrolytic capacitors and make sure all stored energy is gone.
  3. Disassemble the outdoor PCB or the IPM board.
  4. Measure resistance between P and U, V, W, N, and between U, V, W and N, using the diode-style reference in Fig. 21.
  5. Compare readings with the reference table; replace the IPM board or outdoor PCB if they do not match.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

Source: DLFSHC Service Manual, p. 28. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service