Viessmann DLCURAQ30AB3 Error Codes

Updated · by Aurora Star Tech Inc.

Viessmann DLCURAQ30AB3 error codes and diagnostic codes. The DLCURAQ30AB3 is a Viessmann heat pump in the Vitocal 100-S series.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Viessmann DLCURAQ30AB3 error codes list

CodeMeaningSeverity
DFDefrost display (normal)Low
EC5CHigh pressure sensor failureMedium
EC50Outdoor temperature sensor errorLow
EC57Refrigerant pipe temperature sensor errorLow
EC 72Missing phase failure of outdoor DC fan motorHigh
EC72Lack phase failure of outdoor DC fan motorHigh
EH 62Open or short circuit of temperature sensorMedium
EH 65Open or short circuit of temperature sensorMedium
EL 16Communication malfunction between adapter board and outdoor main boardHigh
EL16Communication fault between outdoor main board and transit boardMedium
FCFC display (normal)Low
FL 09Indoor and outdoor unit mismatchHigh
LC 06IPM module high temperature protectionHigh
LC06High temperature protection of inverter module (IPM)Critical
PC 0AHigh temperature protection of condenserHigh
PC0AHigh temperature protection of condenserMedium
PC 0FPFC module protectionHigh
PC0FPFC module protectionCritical
PC0LLow temperature protection of outdoor unitMedium
PC03Low pressure protectionHigh
PC04Inverter compressor drive errorHigh
PC 06Discharge temperature protection of compressorHigh
PC06Discharge temperature protection of compressorHigh
PC 08Current overload protectionHigh
PC10Outdoor unit low AC voltage protectionMedium
PC11Main control board DC bus high voltage protectionHigh
PC12Main control board DC bus high voltage protection / 341 MCE errorHigh
PC 30High pressure protectionHigh
PC30System high pressure protectionCritical
PC 31Low pressure protectionHigh
PC31System low pressure protectionHigh
PC 40Communication error between outdoor main PCB and IPM boardHigh
PC40Communication error between outdoor main chip and compressor driven chipMedium
PC 41Outdoor compressor current sampling circuit failureMedium
PC42Compressor start failureHigh
PC 43Outdoor compressor lack phase protectionHigh
PC43Outdoor compressor lack phase protectionHigh
PC 44Outdoor unit zero speed protectionHigh
PC44Outdoor unit zero speed protectionHigh
PC 45Outdoor unit IR chip drive failureHigh
PC45Outdoor unit IR chip drive failureHigh
PC 46Compressor speed out of controlHigh
PC46Compressor speed out of controlHigh
PC 49Compressor overcurrent failureHigh
PC49Compressor overcurrent failureCritical
PH90High temperature protection of evaporatorMedium
PH91Low temperature protection of evaporatorMedium

Troubleshooting the DLCURAQ30AB3

All Viessmann Heat Pump error codes →

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.