Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code EH0E: Water-level alarm malfunction (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EH0E on a heat pump means: Water-level alarm malfunction. It is also called Viessmann diagnostic code EH0E.

Low severityHeat PumpVitocal IND-A

Homeowner? What Viessmann code EH0E means for you

Usually minor Your heat pump is reporting: Water-level alarm malfunction. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EH0E mean?

The water-level sensing voltage is not 5 V, so the LED shows this fault.

Applies to: Models 18XAK, 24XAK, 30XAK, 36XAK, 48XAK, 60XAK

Common causes of Viessmann code EH0E

  • Water-level switch not seated properly
  • Broken water-level switch
  • Connection wire fault

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
EC 72Missing phase failure of outdoor DC fan motor
EC72Lack phase failure of outdoor DC fan motor
EC73Zero-speed failure of outdoor DC fan motor
EH(xx)Indoor unit error code EH(xx)
EH 0bCommunication error between display board and main board
EH 0EWater-level alarm malfunction
EH00EEPROM parameter error
EH00/EH0AIndoor unit EEPROM parameter error
EH02Zero crossing detection error
EH 03Indoor fan speed outside normal range
EH03Indoor fan speed outside normal range
EH06Indoor PCB and display board communication error

All Viessmann Heat Pump error codes →

Viessmann code EH0E: homeowner questions

What does Viessmann code EH0E mean?

Water-level alarm malfunction. The water-level sensing voltage is not 5 V, so the LED shows this fault.

Is it safe to keep using my heat pump with code EH0E?

Usually yes. Code EH0E is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code EH0E myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EH0E comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EH0E near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFUAA Service Manual (Viessmann Vitocal IND-A), p. 25. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977