Outdoor unit panel removal, sizes 12 (115V) and 6-12K (208/230V) on a Viessmann heat pump: Order of panel removal for the outdoor unit. Photos in the manual are for reference and may differ from the actual unit.
Applies to: DLCSRB sizes 06 to 12 (12 at 115V; 6-12K at 208/230V)
How to fix outdoor unit panel removal, sizes 12 (115v) and 6-12k (208/230v): step by step
- Turn off the air conditioner and the power breaker.
- Remove the handle screw (1) and take off the handle.
- Remove the top cover screws (4); one is under the big handle. Lift off the top cover.
- Remove the water collecting cover screws (2) and take off the water collecting cover.
- Remove the front panel screws: 7 screws on on/off models, 9 screws on inverter models. Take off the front panel.
- Remove the right panel screws (5) and take off the right panel.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3
Source: Viessmann DLCSRB service manual, p. 56-58. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.