Viessmann Heat Pump: Ice build-up on outdoor unit
Ice build-up on outdoor unit on a Viessmann heat pump: Ice in the condensate pan or fan area can damage the unit.
Applies to: Vitocal 100-AW AM2V outdoor unit
How to fix ice build-up on outdoor unit: step by step
- Do not use mechanical items or aids to remove ice.
- Check the refrigerant circuit for leaks before using any electric heating appliance nearby, and make sure the heater is not an ignition source.
- Where ice builds up often, fit fan ring heating suitable for R32 and/or an electric ribbon heater in the condensate pan (accessory or factory-fitted).
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078
Source: Vitocal 100-AW AM2V installation manual, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.