Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Boiler Error Codes

Updated · by Aurora Star Tech Inc.

121 Navien Boiler error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Navien Boiler error codes list

CodeMeaningSeverity
2nd ignition - No. of TimesEMS Data counter 4Low
3rd ignition - No. of TimesEMS Data counter 5Low
4th ignition - No. of TimesEMS Data counter 6Low
5~10th ignition - No. of TimesEMS Data counter 7Low
AHU connection iconAir handler connectionLow
AHU SH Set TempStatus Information item 5 - AHU SH Set TempLow
Air Handler Interface Output StatusInput/Output Status item 15 - Air Handler Interface Output StatusLow
Approx. Boiler FlowStatus Information item 11 - Approx. Boiler FlowLow
Auto air purge iconAuto air purge runningLow
Boiler Pump StatusInput/Output Status item 5 - Boiler Pump StatusLow
Boost Interval TimeStatus Information item 23 - Boost Interval TimeLow
Cascade/Main iconCascade main unitLow
Combustion iconBurner combustingLow
DHW/Zone1 Pump StatusInput/Output Status item 6 - DHW/Zone1 Pump StatusLow
DHW demand iconDHW demand presentLow
DHW Operation TimeService Status Info item 2 - DHW Operation TimeLow
DHW priority iconDHW priority enabledLow
DHW Priority Output StatusInput/Output Status item 16 - DHW Priority Output StatusLow
DHW Set TempStatus Information item 4 - DHW Set TempLow
DHW Tank set TempStatus Information item 12 - DHW Tank set TempLow
DHW temperatureDHW temperature displayLow
DHW Thermostat StatusInput/Output Status item 4 - DHW Thermostat StatusLow
Dual Venturi StatusInput/Output Status item 13 - Dual Venturi StatusLow
E001Heat exchanger overheatHigh
E003Ignition failureHigh
E004False flame detectedHigh
E012Flame lossHigh
E016Heat exchanger overheat (check flow / system filters)High
E020Abnormal Gas Control ValveCritical
E030Exhaust overheatHigh
E031Burner overheatHigh
E046Heat exchanger thermistor faultMedium
E047Exhaust thermistor faultMedium
E060Dual venturi faultMedium
E109Fan motor faultHigh
E110Exhaust blockageHigh
E123Abnormal Fan Motor BlowerHigh
E205Heating supply temperature sensorMedium
E218Heating return temperature sensorMedium
E278External system supply sensor not detectedMedium
E279External system return sensor not detectedMedium
E291Return temperature higher than supplyMedium
E302Low water pressureHigh
E352High water pressureHigh
E353Water pressure sensor faultMedium
E407Dom. Hot Water Outlet SensorMedium
E421Dom. Cold Water Inlet SensorMedium
E434Abnormal Water Adjust ValveMedium
E439No Dom. Water Flow DetectedMedium
E441Domestic hot water outlet 2 sensor faultMedium
E445Abnormal mixing valveHigh
E480DHW tank sensor not detectedLow
E515PCB faultMedium
E517DIP switch setting faultMedium
E593Abnormal panel keyHigh
E594EEPROM faultMedium
E598RTC communication abnormalityHigh
E615Memory faultMedium
E736Cascade communication faultMedium
E740Outdoor sensor not detectedMedium
E761Pump aquastat not detectedMedium
E762Vent pipe not fully inserted (VID)Critical
E773Wrong gas type detectedMedium
E777Low water cutoff activatedHigh
E782Front panel communication faultMedium
E784Zone controller communication faultMedium
E786Improper front panel detectedMedium
E788Incorrect gas type settingHigh
Elapsed Time After InstallEMS Data counter 1Low
EMS DataEMS Data menu (history counters)Low
Error HistoryError history listLow
Exhaust TempStatus Information item 20 - Exhaust TempLow
Fan Current APSStatus Information item 19 - Fan Current APSLow
Fan Current RPMStatus Information item 17 - Fan Current RPMLow
Fan Target APSStatus Information item 18 - Fan Target APSLow
Fan Target RPMStatus Information item 16 - Fan Target RPMLow
Flame Loss - No. of TimesEMS Data counter 3Low
Flame ValueStatus Information item 15 - Flame ValueLow
Freeze Protection iconFreeze protection mode activeLow
GasStatus Information item 26 - GasLow
Gas ConsumptionService Status Info item 3 - Gas ConsumptionLow
Heat CapacityStatus Information item 2 - Heat CapacityLow
HEX Overheat - No. of TimesEMS Data counter 2Low
High AltitudeStatus Information item 24 - High AltitudeLow
HTL Input StatusInput/Output Status item 12 - HTL Input StatusLow
LWCO Input StatusInput/Output Status item 14 - LWCO Input StatusLow
Main F/W VerStatus Information item 27 - Main F/W VerLow
Main MenuMain menuLow
ModelStatus Information item 25 - ModelLow
Operation StateStatus Information item 1 - Operation StateLow
Outdoor ResetStatus Information item 21 - Outdoor ResetLow
Outdoor Reset CurveStatus Information item 22 - Outdoor Reset CurveLow
Outdoor reset iconOutdoor reset enabledLow
Outdoor TempStatus Information item 10 - Outdoor TempLow
Outdoor temperatureOutdoor temperature displayLow
Panel F/W VerStatus Information item 28 - Panel F/W VerLow
Return TempStatus Information item 7 - Return TempLow
Service menuAdvanced / service menu (Back + Menu)Low
SH1 Thermostat StatusInput/Output Status item 1 - SH1 Thermostat StatusLow
SH2 Thermostat StatusInput/Output Status item 2 - SH2 Thermostat StatusLow
SH3 Thermostat StatusInput/Output Status item 3 - SH3 Thermostat StatusLow
SH Operation TimeService Status Info item 1 - SH Operation TimeLow
SH Set TempStatus Information item 3 - SH Set TempLow
Space heating demand iconSpace heating demandLow
Space heating temperatureSpace heating temperature displayLow
Status InformationStatus Information menuLow
Supply Limit - No. of TimesEMS Data counter 9Low
Supply TempStatus Information item 6 - Supply TempLow
Sys Return TempStatus Information item 9 - Sys Return TempLow
Sys Supply TempStatus Information item 8 - Sys Supply TempLow
system/Zone3 Pump StatusInput/Output Status item 8 - system/Zone3 Pump StatusLow
System check iconSystem check or error neededLow
System pressureSystem pressure displayLow
Tank Sensor TempStatus Information item 13 - Tank Sensor TempLow
Water PressStatus Information item 14 - Water PressLow
Zone2 Pump StatusInput/Output Status item 7 - Zone2 Pump StatusLow
Zone V/V 1 StatusInput/Output Status item 9 - Zone V/V 1 StatusLow
Zone V/V 2 StatusInput/Output Status item 10 - Zone V/V 2 StatusLow
Zone V/V 3 StatusInput/Output Status item 11 - Zone V/V 3 StatusLow
△T High - No. of TimesEMS Data counter 10Low
△T Limit - No. of TimesEMS Data counter 8Low

Find codes by Navien model

Navien NFB-H

NFB-175HNFB-200H

Navien NHB-H

NHB-055HNHB-080HNHB-110HNHB-150H

Boiler troubleshooting guides

Navien Boiler specs and setup data

Homeowner help: Boiler Not Heating: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977