Navien Boiler: Derating at high altitude

Updated · by Aurora Star Tech Inc.

Derating at high altitude on a Navien boiler: Above 2,000 ft the boiler derates about 3% per 1,000 ft on natural gas and 4% or more per 1,000 ft on propane. Above 5,400 ft on NG, change to the high altitude orifice.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 high altitude installs up to 10,100 ft

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

More other tips for boiler

Source: Navien NCB700 installation and operation manual, p. 142. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.