Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code DHW Thermostat Status: Input/Output Status item 4 – DHW Thermostat Status (Boiler)

Updated · by Aurora Star Tech Inc.

Navien error code DHW Thermostat Status on a boiler means: Input/Output Status item 4 - DHW Thermostat Status. It is also called Navien diagnostic code DHW Thermostat Status.

Low severityBoilerNavien NHB-H

Homeowner? What Navien code DHW Thermostat Status means for you

Usually minor Your boiler is reporting: Input/Output Status item 4 - DHW Thermostat Status. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code DHW Thermostat Status mean?

Service menu 2. Input/Output Status, item 4: shows the state of the DHW thermostat 1 input. Useful to see whether the control is seeing or sending a signal.

Applies to: NHB-055H, NHB-080H, NHB-110H, NHB-150H

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code DHW Thermostat Status

NHB-055HNHB-080HNHB-110HNHB-150H

Other Navien Boiler codes

CodeMeaning
DHW Operation TimeService Status Info item 2 - DHW Operation Time
DHW priority iconDHW priority enabled
DHW Priority Output StatusInput/Output Status item 16 - DHW Priority Output Status
DHW Set TempStatus Information item 4 - DHW Set Temp
DHW Tank set TempStatus Information item 12 - DHW Tank set Temp
DHW temperatureDHW temperature display
Dual Venturi StatusInput/Output Status item 13 - Dual Venturi Status
E001Heat exchanger overheat
E003Ignition failure
E004False flame detected
E012Flame loss
E016Heat exchanger overheat (check flow / system filters)

All Navien Boiler error codes →

Navien code DHW Thermostat Status: homeowner questions

What does Navien code DHW Thermostat Status mean?

Input/Output Status item 4 - DHW Thermostat Status. Service menu 2. Input/Output Status, item 4: shows the state of the DHW thermostat 1 input. Useful to see whether the control is seeing or sending a signal.

Is it safe to keep using my boiler with code DHW Thermostat Status?

Usually yes. Code DHW Thermostat Status is normally minor, but if it keeps coming back have it checked.

Can I reset Navien code DHW Thermostat Status myself?

You can try one reset (power off for 30 seconds, then on). If Navien code DHW Thermostat Status comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code DHW Thermostat Status near me?

Aurora Star Tech Inc. repairs Navien boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Navien NHB-H Installation and Operation Manual, 11.13.2 Viewing Input and Output Status, p.110-111. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair