Connecting Ready-Link communication cables on a Navien boiler: Connect the cascade units with Ready-Link cables. All units must be powered off before connecting.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 cascade with NPE-A2 or NPE-S2 water heaters

How to fix connecting ready-link communication cables: step by step

  1. Make sure power is off to all units.
  2. Connect the Ready-Link cables to the CNK1 terminal strip on the NCB700.
  3. Connect the Ready-Link cables to the J6 ports on the left side of the front panel of each NPE-A2 water heater.
  4. Restore power to the boiler and turn all boilers on with the Power button.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien NCB700 installation and operation manual, p. 87. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.