Navien Boiler: Condensate drain connection
Condensate drain connection on a Navien boiler: Condensate must drain from the 3/4 in condensate outlet, and the trap must be primed with water.
Applies to: NFB-301C/399C
How to fix condensate drain connection: step by step
- Connect the drain pipe to the 3/4 in NPT condensate outlet at the bottom of the unit.
- Pour water into the exhaust connection to fill the condensate trap.
- Drain the pipe end to a laundry tub or floor drain, or use an allowed external drain, neutralizer or condensate pump.
- Do not submerge the pipe end in water.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NFB-C quick installation guide, p. 2. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.