Navien Boiler: Combustion air location and contaminant avoidance
Combustion air location and contaminant avoidance on a Navien boiler: Choose the combustion air source and location to avoid contaminated air. Use direct venting (outside air) where contaminants are present. Carbon monoxide detectors may be required by local code. Detectors must meet NFPA 720, be ANSI/UL 2034 listed and IAS approved. The warranty does not cover damage caused by airborne contaminants.
Applies to: NCB700 combustion air
Common causes of combustion air location and contaminant avoidance
- Corrosive contaminants in the combustion air, such as muriatic or hydrochloric acid, refrigerant leaks, solvents, detergents and chlorine bleach, paint or varnish solvents, construction adhesives, chlorine pool chemicals, hair perm solutions, anti-static dryer sheets, calcium chloride de-icer salt, chlorocarbon or fluorocarbon aerosols, adhesives and glues, sodium chloride water softener salt, and chlorine-based waxes or cleaners.
- Corrosive sources by location: renovation zones, refrigeration repair shops, new construction, metal fabrication plants, laundries and dry cleaners, swimming pools, auto body shops, furniture finishing, garages with workshops, plastics plants, beauty salons, and photo processing shops.
How to fix combustion air location and contaminant avoidance: step by step
- Check the area and the products listed in the tables before installing the boiler and the air intake piping.
- Remove the contaminant source or move the air intake and vent terminations to a clean area.
- Use direct venting to bring clean outside air to the boiler where the room air is contaminated.
- Clean and service the air filter regularly if the boiler is installed in such an area.
- Do not let pool, laundry or household cleaning chemical liquids or vapors enter the boiler.
- Do not install the boiler or combustion air piping in an area with contaminated air.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation & operation manual, pp. 230-232. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.