Navien Boiler: No water at all when the hot water tap is opened
No water at all when the hot water tap is opened on a Navien boiler: Basic FAQ troubleshooting. The flow chart layout is hard to read, so the checks below are grouped by likely cause.
Applies to: CH combination boiler
Common causes of no water at all when the hot water tap is opened
- Shut-off valve on hot or cold pipe closed
- Cold water inlet filter dirty
- Error code shown on remote controller
- Unit frozen
- Cross-plumbing between cold and hot lines
- Hot water fixture not open enough to draw at least 0.5 GPM through the boiler
How to fix no water at all when the hot water tap is opened: step by step
- Make sure the shut-off valves on the hot and cold pipes are open.
- Check whether the cold water filter is clean.
- Check the remote controller for a flashing error code.
- Check whether the unit is frozen.
- Check for cross-plumbing between cold and hot water lines.
- Make sure the hot water fixture is open enough to draw at least 0.5 GPM through the boiler.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien CH User's Operation Manual, p. 40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.