Navien Boiler: Refilling the space heating side with the auto feeder
Refilling the space heating side with the auto feeder on a Navien boiler: The built-in automatic feeder fills the space heating side and stops on its own. Bleed air and check for leaks before restarting.
Applies to: CH combination boiler
How to fix refilling the space heating side with the auto feeder: step by step
- Confirm the pump drain plug and DHW cold water inlet filter are installed and the drain fittings inside the unit are closed.
- Slowly open the water supply valve on the unit inlet, or open the supply at the water meter slowly if there is no valve.
- Check the unit for water leaks.
- Let the auto feeder fill the space heating side and stop.
- Check the manual air release to confirm the system filled properly.
- Bleed all air from the hot water lines, then close all hot water faucets.
- Turn power on to the unit.
- Open the gas valve.
- Open a hot water faucet to test. The unit should fire and run normally.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien CH User's Operation Manual, p. 34. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.