Navien Error Codes & Diagnostic Codes

Updated · by Aurora Star Tech Inc.

Navien error codes and diagnostic codes: look up a code to see what it means, the likely causes and the steps to fix it.

Navien error codes by equipment type

Navien Air Conditioner error codes

CodeMeaning
A251Alarm: PD high pressure protection
A252Alarm: PS low pressure protection
A253Alarm: TD discharge temperature protection
A254Alarm: CR compression ratio protection
A255Alarm: CUR overcurrent protection
A256Alarm: heatsink protection
A257Alarm: compressor temperature abnormal protection
A258Alarm: TS suction temperature protection
A259Alarm: superheat protection
A260Alarm: high pressure switch (HPS) protection
A851Inverter trip alarm: Communication error
A852Inverter trip alarm: Compressor current sensor error
A853Inverter trip alarm: DC link sensor error
A854Inverter trip alarm: PFCM current A error
A855Inverter trip alarm: PFCM current B error
A856Inverter trip alarm: Input voltage sensor error
A857Inverter trip alarm: Software compressor overcurrent
A858Inverter trip alarm: Overcurrent at compressor current limit
A859Inverter trip alarm: Overcurrent at ID current limit
A860Inverter trip alarm: Hardware compressor overcurrent
A861Inverter trip alarm: PFC overcurrent
A862Inverter trip alarm: Estimator fault
A863Inverter trip alarm: Compressor starting error
A864Inverter trip alarm: Wire miss error
A865Inverter trip alarm: Heatsink over temperature
A866Inverter trip alarm: DC under voltage
A867Inverter trip alarm: DC over voltage
A868Inverter trip alarm: AC under voltage
A869Inverter trip alarm: AC over voltage
A870Inverter trip alarm: PFC unbalanced current
A871Inverter trip alarm: Fan motor error (5 min)
A872Inverter trip alarm: Discharge FET error
A873Inverter trip alarm: Stator overheat (5 min)
A874Inverter trip alarm: PBA (power board) over temperature
ATLOutdoor temperature outside operating range
d0Oil return cycle
dCForced cooling
E201High pressure (PD) protection error
E202Low pressure (PS) protection error
E203Compressor discharge temperature (TD) protection error
E204Compression ratio (CR) protection error
E205Overcurrent (CUR) protection error
E206Heatsink protection error
E207Compressor temperature abnormal error
E208Compressor suction temperature (TS) protection error
E209Superheat protection error
E210High pressure switch (HPS) protection error
E501Outdoor temperature sensor (Ta) open/short
E505Compressor discharge temperature sensor (TD) open/short
E506Compressor suction temperature sensor (TS) open/short
E507Condenser outlet temperature sensor (Tcond) open/short
E561Discharge pressure sensor (PD) open/short
E562Suction pressure sensor (PS) open/short
E702Outdoor unit to inverter driver communication failure
E801Inverter trip: Communication error
E802Inverter trip: Compressor current sensor error
E803Inverter trip: DC link sensor error
E804Inverter trip: PFCM current A error
E805Inverter trip: PFCM current B error
E806Inverter trip: Input voltage sensor error
E807Inverter trip: Software compressor overcurrent
E808Inverter trip: Overcurrent at compressor current limit
E809Inverter trip: Overcurrent at ID current limit
E810Inverter trip: Hardware compressor overcurrent
E811Inverter trip: PFC overcurrent
E812Inverter trip: Estimator fault
E813Inverter trip: Compressor starting error
E814Inverter trip: Wire miss error
E815Inverter trip: Heatsink over temperature
E816Inverter trip: DC under voltage
E817Inverter trip: DC over voltage
E818Inverter trip: AC under voltage
E819Inverter trip: AC over voltage
E820Inverter trip: PFC unbalanced current
E821Inverter trip: Fan motor error (5 min)
E822Inverter trip: Discharge FET error
E823Inverter trip: Stator overheat (5 min)
E824Inverter trip: PBA (power board) over temperature
E999Error of unknown cause
F0Communication fault (outdoor unit)
F1Low pressure switch fault
F4T4 outdoor ambient sensor fault
F5T5 compressor discharge sensor fault
F6T3 condenser coil sensor fault
F7T7 sensor fault
F8T7 sensor: condensate risk on the cooling plate
F9Line voltage too low or too high
FAOutdoor board memory (EEPROM) fault
FBDrive chip memory (EEPROM) fault
FCDrive module temperature sensor fault
FDPressure sensor not detected
FET3 or T5 probe out of position
FFHigh pressure switch reads open all the time
H0Communication fault between chips on the outdoor PCB
H1Lockout: outdoor coil too hot (P5 repeated)
H2Lockout: high pressure switch (P1 repeated)
H3High pressure abnormal (sensor over 3.6 MPa) - heating mode
H4Lockout: drive module overheating (P8 repeated)
H5Lockout: low pressure (P2 repeated)
H6Lockout: high discharge temperature (P4 repeated)
H7Lockout: low discharge superheat (PC repeated)
H8Lockout: T3 probe off the pipe (FE repeated)
HCLockout: discharge probe off the pipe (FE repeated)
HERepeated condensate-risk faults (F8)
HICharging mode: outdoor air too hot
L0DC bus voltage too low
L1DC bus voltage too high
LACompressor speed held back by voltage
LBCompressor speed held back by high pressure
LCCompressor speed held back by condenser temperature
LDCompressor speed held back by discharge temperature
LECompressor speed held back by drive module temperature
LFCompressor speed held back by current
LOCharging mode: outdoor air too cold
P1High pressure switch opened
P2Low pressure protection
P3Compressor drive overcurrent
P4Discharge temperature too high
P5Condenser coil (T3) temperature too high - cooling
P6Compressor drive (IPM) module protection
P8Drive module (IPM) overheating
P9Outdoor fan motor fault
PCLow discharge superheat (liquid floodback risk)
PC, H7Moisture exposure error (overheat, T5-T3 under 9°F / 5°C)
PDHigh pressure too high
PRHCrankcase heater warm-up, no start yet
R101Condenser heat exchange abnormal alarm
R301Supply solenoid valve stuck alarm
R302Drain solenoid valve stuck alarm
R303Water supply abnormality alarm
R563Water pressure sensor open/short alarm
R601EEPROM alarm
R602NOR flash alarm
R881Inverter minor: IPM temperature sensor error
R882Inverter minor: PFCM temperature sensor error
R883Inverter minor: ID current limit minor
R884Inverter minor: Compressor current limit minor
R885Inverter minor: AC over voltage
R886Inverter minor: PFC overcurrent
R887Inverter minor: Input current limit
ST.10Standby
ST.20Initial startup
ST.30Normal operation
ST.40Post-stop delay
THCharging mode: no thermostat call

Navien Boiler error codes

CodeMeaning
2nd ignition - No. of TimesEMS Data counter 4
3rd ignition - No. of TimesEMS Data counter 5
4th ignition - No. of TimesEMS Data counter 6
5~10th ignition - No. of TimesEMS Data counter 7
AHU connection iconAir handler connection
AHU SH Set TempStatus Information item 5 - AHU SH Set Temp
Air Handler Interface Output StatusInput/Output Status item 15 - Air Handler Interface Output Status
Approx. Boiler FlowStatus Information item 11 - Approx. Boiler Flow
Auto air purge iconAuto air purge running
Boiler Pump StatusInput/Output Status item 5 - Boiler Pump Status
Boost Interval TimeStatus Information item 23 - Boost Interval Time
Cascade/Main iconCascade main unit
Combustion iconBurner combusting
DHW/Zone1 Pump StatusInput/Output Status item 6 - DHW/Zone1 Pump Status
DHW demand iconDHW demand present
DHW Operation TimeService Status Info item 2 - DHW Operation Time
DHW priority iconDHW priority enabled
DHW Priority Output StatusInput/Output Status item 16 - DHW Priority Output Status
DHW Set TempStatus Information item 4 - DHW Set Temp
DHW Tank set TempStatus Information item 12 - DHW Tank set Temp
DHW temperatureDHW temperature display
DHW Thermostat StatusInput/Output Status item 4 - DHW Thermostat Status
Dual Venturi StatusInput/Output Status item 13 - Dual Venturi Status
E001Heat exchanger overheat
E003Ignition failure
E004False flame detected
E012Flame loss
E016Heat exchanger overheat (check flow / system filters)
E020Abnormal Gas Control Valve
E030Exhaust overheat
E031Burner overheat
E046Heat exchanger thermistor fault
E047Exhaust thermistor fault
E060Dual venturi fault
E109Fan motor fault
E110Exhaust blockage
E123Abnormal Fan Motor Blower
E205Heating supply temperature sensor
E218Heating return temperature sensor
E278External system supply sensor not detected
E279External system return sensor not detected
E291Return temperature higher than supply
E302Low water pressure
E352High water pressure
E353Water pressure sensor fault
E407Dom. Hot Water Outlet Sensor
E421Dom. Cold Water Inlet Sensor
E434Abnormal Water Adjust Valve
E439No Dom. Water Flow Detected
E441Domestic hot water outlet 2 sensor fault
E445Abnormal mixing valve
E480DHW tank sensor not detected
E515PCB fault
E517DIP switch setting fault
E593Abnormal panel key
E594EEPROM fault
E598RTC communication abnormality
E615Memory fault
E736Cascade communication fault
E740Outdoor sensor not detected
E761Pump aquastat not detected
E762Vent pipe not fully inserted (VID)
E773Wrong gas type detected
E777Low water cutoff activated
E782Front panel communication fault
E784Zone controller communication fault
E786Improper front panel detected
E788Incorrect gas type setting
Elapsed Time After InstallEMS Data counter 1
EMS DataEMS Data menu (history counters)
Error HistoryError history list
Exhaust TempStatus Information item 20 - Exhaust Temp
Fan Current APSStatus Information item 19 - Fan Current APS
Fan Current RPMStatus Information item 17 - Fan Current RPM
Fan Target APSStatus Information item 18 - Fan Target APS
Fan Target RPMStatus Information item 16 - Fan Target RPM
Flame Loss - No. of TimesEMS Data counter 3
Flame ValueStatus Information item 15 - Flame Value
Freeze Protection iconFreeze protection mode active
GasStatus Information item 26 - Gas
Gas ConsumptionService Status Info item 3 - Gas Consumption
Heat CapacityStatus Information item 2 - Heat Capacity
HEX Overheat - No. of TimesEMS Data counter 2
High AltitudeStatus Information item 24 - High Altitude
HTL Input StatusInput/Output Status item 12 - HTL Input Status
LWCO Input StatusInput/Output Status item 14 - LWCO Input Status
Main F/W VerStatus Information item 27 - Main F/W Ver
Main MenuMain menu
ModelStatus Information item 25 - Model
Operation StateStatus Information item 1 - Operation State
Outdoor ResetStatus Information item 21 - Outdoor Reset
Outdoor Reset CurveStatus Information item 22 - Outdoor Reset Curve
Outdoor reset iconOutdoor reset enabled
Outdoor TempStatus Information item 10 - Outdoor Temp
Outdoor temperatureOutdoor temperature display
Panel F/W VerStatus Information item 28 - Panel F/W Ver
Return TempStatus Information item 7 - Return Temp
Service menuAdvanced / service menu (Back + Menu)
SH1 Thermostat StatusInput/Output Status item 1 - SH1 Thermostat Status
SH2 Thermostat StatusInput/Output Status item 2 - SH2 Thermostat Status
SH3 Thermostat StatusInput/Output Status item 3 - SH3 Thermostat Status
SH Operation TimeService Status Info item 1 - SH Operation Time
SH Set TempStatus Information item 3 - SH Set Temp
Space heating demand iconSpace heating demand
Space heating temperatureSpace heating temperature display
Status InformationStatus Information menu
Supply Limit - No. of TimesEMS Data counter 9
Supply TempStatus Information item 6 - Supply Temp
Sys Return TempStatus Information item 9 - Sys Return Temp
Sys Supply TempStatus Information item 8 - Sys Supply Temp
system/Zone3 Pump StatusInput/Output Status item 8 - system/Zone3 Pump Status
System check iconSystem check or error needed
System pressureSystem pressure display
Tank Sensor TempStatus Information item 13 - Tank Sensor Temp
Water PressStatus Information item 14 - Water Press
Zone2 Pump StatusInput/Output Status item 7 - Zone2 Pump Status
Zone V/V 1 StatusInput/Output Status item 9 - Zone V/V 1 Status
Zone V/V 2 StatusInput/Output Status item 10 - Zone V/V 2 Status
Zone V/V 3 StatusInput/Output Status item 11 - Zone V/V 3 Status
△T High - No. of TimesEMS Data counter 10
△T Limit - No. of TimesEMS Data counter 8

Navien Combi Boiler error codes

CodeMeaning
AHU connection iconAir handler connection
AHU SH Set TempStatus Information item 5 - AHU SH Set Temp
Anti-freeze iconAnti-freeze mode active
Approx. Boiler FlowStatus Information item 14 - Approx. Boiler Flow
Auto air purge iconAuto air purge running
Boost Interval TimeStatus Information item 27 - Boost Interval Time
Cascade/Main iconCascade main unit
Combustion iconBurner combusting
DHW demand iconDHW demand present
DHW FlowStatus Information item 15 - DHW Flow
DHW operation iconDHW preheat feature active
DHW Set TempStatus Information item 4 - DHW Set Temp
DHW set temperatureDHW set temperature display
E001Heat exchanger overheat
E002Low pressure on the heating side
E003Ignition failure
E004False flame detected
E005Heating supply sensor open
E006Heating supply sensor shorted
E007DHW outlet sensor open
E008DHW outlet sensor shorted
E009Fan motor fault
E010Air pressure fault
E011High pressure on the heating side
E012Flame loss
E013Pump fault
E015PCB fault
E016Heat exchanger overheat (overheating of heat exchanger)
E018Heating return sensor open
E019Heating return sensor shorted
E021DHW cold inlet sensor open
E022DHW cold inlet sensor shorted
E027Air pressure sensor fault
E028Leak on the heating side
E030Exhaust overheat (abnormal exhaust temperature)
E031Burner overheat
E035Gas pressure sensor fault
E036Communication failure
E037Water leak inside the unit
E039Flow sensor fault
E040Outdoor sensor shorted
E046Heat exchanger thermistor / overheat sensor fault
E047Exhaust thermistor fault
E048Low LP gas pressure (propane models)
E060Dual venturi fault
E109Fan motor fault
E110Exhaust blockage / abnormal air pressure (APS)
E205Heating supply temperature sensor fault
E218Heating return temperature sensor fault
E278External (system) supply sensor not detected
E279External (system) return sensor not detected
E302Low water pressure (internal LWCO)
E351Auto feeder (make-up water) valve fault
E352High water pressure
E353Water pressure sensor fault
E407DHW outlet temperature sensor fault
E421DHW cold water inlet sensor fault
E434Water adjustment (flow control) valve fault
E439No DHW flow detected / flow sensor fault
E441DHW outlet 2 sensor fault
E445Mixing (bypass) valve fault
E515PCB fault
E517DIP switch setting fault
E594EEPROM fault
E615Memory fault (input and memory)
E736Cascade communication fault
E740Outdoor sensor not detected
E761Pump aquastat (pre-heat aquastat) not detected
E762Vent pipe not fully inserted (VID)
E773Improper gas type detected
E777Low water cutoff (LWCO) activated
E782Front panel communication fault
E784Zone controller communication fault
E786Improper front panel
E788Incorrect gas type setting
Exhaust TempStatus Information item 24 - Exhaust Temp
Fan Current APSStatus Information item 21 - Fan Current APS
Fan Current RPMStatus Information item 19 - Fan Current RPM
Fan Target APSStatus Information item 20 - Fan Target APS
Fan Target RPMStatus Information item 18 - Fan Target RPM
Flame ValueStatus Information item 17 - Flame Value
Flow Control ValveStatus Information item 22 - Flow Control Valve
GasStatus Information item 31 - Gas
Heat CapacityStatus Information item 2 - Heat Capacity
High AltitudeStatus Information item 28 - High Altitude
Inlet TempStatus Information item 12 - Inlet Temp
Main F/W VerStatus Information item 32 - Main F/W Ver
Mixing ValveStatus Information item 23 - Mixing Valve
ModelStatus Information item 30 - Model
Operation StateStatus Information item 1 - Operation State
Outdoor ResetStatus Information item 25 - Outdoor Reset
Outdoor Reset CurveStatus Information item 26 - Outdoor Reset Curve
Outdoor reset iconOutdoor reset enabled
Outdoor TempStatus Information item 13 - Outdoor Temp
Outdoor temperatureOutdoor temperature display
Outlet2 TempStatus Information item 10 - Outlet2 Temp
Outlet TempStatus Information item 11 - Outlet Temp
Panel F/W VerStatus Information item 33 - Panel F/W Ver
Return TempStatus Information item 7 - Return Temp
SH Set TempStatus Information item 3 - SH Set Temp
Space heating demand iconSpace heating demand
Space heating set temperatureSpace heating set temperature display
Status InformationStatus Information menu
Supply TempStatus Information item 6 - Supply Temp
Sys Return TempStatus Information item 9 - Sys Return Temp
Sys Supply TempStatus Information item 8 - Sys Supply Temp
System check iconSystem check or error needed
System pressureSystem pressure display
Water PressureStatus Information item 16 - Water Pressure
Well PumpStatus Information item 29 - Well Pump

Navien Furnace error codes

CodeMeaning
1 FlashHigh limit switch open
2 FlashesPressure switch open with inducer on
3 FlashesPressure switch closed with inducer off
4 FlashesControl in 1 hour lockout
5 FlashesL1/Neutral polarity problem
6 FlashesToo many limit trips in one call for heat
7 FlashesPressure switch cycle lockout
8 FlashesLockout due to too many flame dropouts
9 FlashesFlash code 9 not used
10 FlashesFlame present with gas valve off
E003 00Ignition failure
E004 0False flame
E012 00Flame loss during combustion
E016 00Heat exchanger overheating
E030 02Abnormal exhaust gas temperature (lock out)
E031 00Burner overheating
E046 00Abnormal limit control operation on heat exchanger
E047 01Abnormal exhaust temperature sensor operation
E047 02Abnormal exhaust temperature sensor operation
E109 00Abnormal inducer fan operation
E205 01Abnormal supply water temperature sensor, lower limit
E205 02Abnormal supply water temperature sensor, upper limit
E218 01Abnormal return water temperature sensor, lower limit
E218 02Abnormal return water temperature sensor, upper limit
E238 01Abnormal recirculation pump operation
E238 02Abnormal recirculation pump operation
E302 00Low water level
E311 00Abnormal water level sensor
E351 00Abnormal auto water fill
E360 00Abnormal cover opening
E515 01Abnormal WD-PSS1 status
E515 02Abnormal WD-PSS2 status
E515 03Abnormal MGV1 status
E515 04Abnormal MGV2 status
E515 09Abnormal fan control
E515 10Abnormal monitoring device status
E515 16Abnormal AWS feedback
E515 24Abnormal leakage input
E517 00Abnormal DIP switch settings
E593 00Abnormal front panel keys
E594Abnormal EEPROM operation
E594 00Abnormal EEPROM operation
E615Controller fault (sub codes 01, 03, 04, 05)
E615 01Abnormal overheat controller feedback
E615 03Abnormal flame signal input
E615 04Abnormal ADC reference voltage
E615 05Abnormal MCU
E740Abnormal outdoor temperature sensor (sub codes 01, 02)
E740 01, 02Abnormal outdoor temperature sensor operation
E762Vent pipe not detected by Vent Installation Detector (VID)
E762 00Improper vent pipe installation
E774External safety device on IN_1 stops the furnace
E774 00Abnormal external safety system operation 1
E775External safety device on IN_2 stops the furnace (auto reset)
E775 00Abnormal external safety system operation 2
E782Controller to front panel communication error
E782 00Controller to panel communication abnormal
E786Abnormal front control panel connection
E786 00Abnormal front control panel connection
E788Abnormal gas type setting
E788 00Abnormal gas type settings
E799Leak detected (sensor 00, water level 01)
E799 00Leak detected (sensor)
E799 01Leak detected (water level)
E805Abnormal supply air temperature sensor (sub codes 01, 02)
E810Abnormal circulator operation (inoperable), sub codes 00–09
E811Abnormal circulator operation (inoperable)
E818Abnormal return air temperature sensor (sub codes 01, 02)
E822Overcooling of the air conditioning coil (evaporator coil)
E860IAQ replacement alerts (sub codes 01, 02, 03)
E890Abnormal circulator communication
LED FlashingGreen LED flashing, high pressure switch not closed
LED OffRed status LED off
LED ONRed status LED on, normal operation

Navien General error codes

CodeMeaning
001Water leakage
002Water outage
003Water outage during CIP
010High water pressure
020Product flow path clogged
021Regeneration line open
022Regeneration line open
023Bypass line clogged
024Regeneration line clogged
025Regeneration line clogged
026Product water line clogged
027Product water line clogged
041Abnormal NDI module performance
042Abnormal NDI module performance
051Main CIP or TDS sensor relay
052Regeneration line CIP
060Flow sensor fault
061Flow sensor fault
062TDS sensor fault
063TDS sensor fault
064TDS sensor fault
065Pressure sensor fault
066Temperature sensor fault
067Ambient air temperature sensor fault
070Water connection
071Abnormal faucet opening
072Abnormal close of the bypass valve
073Abnormal close of the main valve
074Abnormal open of the main valve
075Abnormal open of the bypass valve
076Abnormal close of the product water valve
077Abnormal close of the regeneration valve
078Abnormal close of the regeneration valve
079Abnormal open of the regeneration valve
080Abnormal open of the regeneration valve
081Abnormal open of the product water valve
082Abnormal open of the product water valve
083Abnormal operation of CIP check
084Abnormal operation of circulation pump check
090Main valve electronics fault
091Bypass valve electronics fault
092Product water valve electronics fault
093Product water valve electronics fault
094Regeneration valve electronics fault
095Regeneration valve electronics fault
096Circulation valve electronics fault
097Circulation valve electronics fault
098CIP pump electronics fault
099Circulation pump valve electronics fault
100Anti-freezing valve electronics fault
105Abnormal RTC
106Abnormal panel key
107Abnormal EEPROM
110Power board overheat
111Over voltage at DC-Link
112Over current at converter
113Over current at module
114Over current at module
115IGBT error
116Over voltage inverter
117Under voltage inverter
118Over frequency inverter
119Under frequency inverter
120AD offset error
122Heat sink sensor error
123Fan error
124Security-chip error
130Power board communication error
615Abnormal memory
E001Leak detected
E002Drain line flow error
E003Drain line flow error
E010High inlet water pressure
E020Bypass or pressure sensor error
E021Regeneration line #1 open error (left)
E022Regeneration line #2 open error (right)
E023Bypass solenoid valve error
E024Regeneration line #1 blockage error (left)
E025Regeneration line #2 blockage error (right)
E026Drain line error (main solenoid path)
E027Drain line error (main solenoid path)
E041TDS sensor error
E042TDS sensor error
E051CIP dosing or circulation error
E060 - E067Individual sensor errors
E070Install Check Mode drain line error
E070 - E084Install Check Mode errors
E071No water to drain line after faucet opened
E072Bypass valve fault
E073Main valve fault
E074Main valve and product water valve fault
E075Bypass valve fault
E076Product water valve fault
E077Left drain regeneration line closed
E078Right drain regeneration line closed
E079Left drain regeneration line opening
E080Right drain regeneration line opening
E081Left product water solenoid valve opening
E082Right product water solenoid valve opening
E083CIP dosing pump fault
E084Circulation pump fault
E090 - E100Individual sensor or pump fault
E105PCB fault
E106PCB or harness fault
E107PCB or harness fault
E110Power unit overheating
E111 - E115Temporary power unit fault
E116Input voltage high
E117Input voltage low
E118Input frequency high
E119Input frequency low
E122Heat sink sensor fault
E123Fan fault
E124Power assembly fault
E130Main panel to power board communication fault

Navien Heat Pump error codes

CodeMeaning
ATLOutdoor temperature outside operating range
d0Oil return cycle
dCForced cooling
dfDefrost
F4T4 outdoor ambient sensor fault
F5T5 compressor discharge sensor fault
F6T3 condenser coil sensor fault
F7T7 sensor fault
F8T7 sensor: condensate risk on the cooling plate
F9Line voltage too low or too high
FAOutdoor board memory (EEPROM) fault
FBDrive chip memory (EEPROM) fault
FCDrive module temperature sensor fault
FDPressure sensor not detected
FET3 or T5 probe out of position
FFHigh pressure switch reads open all the time
H0Communication fault between chips on the outdoor PCB
H1Lockout: outdoor coil too hot (P5 repeated)
H2Lockout: high pressure switch (P1 repeated)
H3Lockout: high pressure in heating (PD repeated)
H4Lockout: drive module overheating (P8 repeated)
H5Lockout: low pressure (P2 repeated)
H6Lockout: high discharge temperature (P4 repeated)
H7Lockout: low discharge superheat (PC repeated)
H8Lockout: T3 probe off the pipe (FE repeated)
HCLockout: discharge probe off the pipe (FE repeated)
HERepeated condensate-risk faults (F8)
IoT LED bootIoT module boot mode
IoT LED pairingIoT module pairing / operation
IoT Wi-Fi LED colorIoT Wi-Fi signal color
L0DC bus voltage too low
L1DC bus voltage too high
LACompressor speed held back by voltage
LBCompressor speed held back by high pressure
LCCompressor speed held back by condenser temperature
LDCompressor speed held back by discharge temperature
LECompressor speed held back by drive module temperature
LFCompressor speed held back by current
P1High pressure switch opened
P2Low pressure protection
P3Compressor drive overcurrent
P4Discharge temperature too high
P5Outdoor coil too hot in cooling
P6Compressor drive (IPM) module protection
P7Indoor coil freeze protection (T2)
P8Drive module (IPM) overheating
P9Outdoor fan motor fault
PCLow discharge superheat (liquid floodback risk)
PDHigh pressure too high in heating
PRHCrankcase heater warm-up, no start yet

Navien Tankless Water Heater error codes

CodeMeaning
CLRAll timers cleared
CombustionCombustion indicator
Combustion/ErrorCombustion / error indicator
E003Ignition failure
E004False flame detection
E012Flame loss
E016Heat exchanger overheating
E030Exhaust overheating
E031Burner overheating
E046Limit control abnormal
E047Exhaust thermistor open or shorted
E056Modulating gas valve fault
E060Dual venturi abnormal
E21No hot water
E109Fan motor abnormal
E110Abnormal air pressure
E127Air pressure sensor (APS) fault
E157Air volume control fault
E170Antifreeze heater open or short
E407Hot water outlet thermistor open or shorted
E421Cold water inlet 1 thermistor open or shorted
E432Cold water inlet 2 thermistor open or shorted
E434Water adjustment valve abnormal
E438Circulation pump abnormal (with air handler)
E439Flow sensor abnormal
E441Hot water inlet 2 thermistor open or shorted
E445Bypass mixing valve abnormal
E515PCB abnormal
E517DIP switch setting abnormal
E593Front panel key abnormal
E594EEPROM abnormal
E615Input and memory abnormal
E736Cascade communication abnormal
E740Outdoor temperature sensor abnormal (with air handler)
E760Flushing / service alarm
E762Vent pipe not properly inserted
E773Wrong gas type detected
E782Main / panel communication abnormal
E785Flow switch / sensor abnormal (with air handler)
E786Abnormal operation: panel connection
E788Gas type mismatch: DIP switch vs panel setting
Error iconError indicator
GasPropane gas indicator
HEATRecirculation started from remote
Hot water recirculation iconHot water recirculation indicator
Hot water set temperatureHot water temperature setting display
ID 1. Allocated!Cascade sub unit ID assigned
MA.00Cascade main unit confirmed
MAINRemote asks for main/sub setting
Main/SubCascade main or sub unit indicator
Master unit iconMaster unit (cascade) indicator
Preheat iconRecirculation schedule / preheat icon
R&D information menuR&D information menu (Power off, key sequence)
Recirculation/Space HeatingRecirculation / space heating indicator
Recirculation mode displayRecirculation mode display
Remote LEDRemote controller LED colour
Remote lock iconRemote lock mode on
Service/Installer menuService / installer menu (Menu + Back)
SL.01Cascade sub unit confirmed
SL.xxSub remote waiting for ID
Start-up wizardFirst power-on start-up wizard
Status/FlowOperation status and flow rate area
SUBRemote set as sub
SYNCRemote synchronizing

Find codes by Navien model

Navien CH ASME

CH-180 ASMECH-210 ASMECH-240 ASME

Navien NAA

NAA17V36NAA17V60

Navien NAE

NAE28V3622A1NAE28V6022A1

Navien NaviCirc

NaviCirc

Navien NAZ

NAZ17V36NAZ17V60

Navien NCB-H

NCB-190/060HNCB-190/080HNCB-240/110HNCB-240/130HNCB-250/150H

Navien NFB-H

NFB-175HNFB-200H

Navien NFC-H

NFC-250/175HNFC-250/200H

Navien NHB-H

NHB-055HNHB-080HNHB-110HNHB-150H

Navien NHW700

NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU

Navien NPE-2

NPE-150S2NPE-180A2NPE-180S2NPE-210A2NPE-210S2NPE-240A2NPE-240S2

Navien NPN

NPN-120ENPN-160ENPN-160UNPN-180ENPN-180UNPN-199ENPN-199U

Navien troubleshooting guides

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.