Navien Boiler: Preparing and cleaning the heating piping
Preparing and cleaning the heating piping on a Navien boiler: Flush the whole heating circuit before connecting it to the boiler to remove debris, flux, solder, sediment and scale.
Applies to: NCB700 heating circuit piping
Common causes of preparing and cleaning the heating piping
- Construction dust, copper burrs, sand or sludge left in the piping
- Old system with flux, grease or carbon residue
How to fix preparing and cleaning the heating piping: step by step
- Clean and flush the whole system before connecting piping to the boiler.
- On renovations, clean all circuit piping including radiators to remove sludge and deposits.
- Use cleaning products made for boiler systems. Use a stronger cleaner for heavy scale or sludge and follow its instructions.
- Use two wrenches when tightening pipe fittings onto the boiler, one to hold the connector and one to turn the fitting.
- Support the piping with its own hangers. Do not let the boiler or its accessories carry the pipe weight.
- Do not solder directly onto water connections; use threaded water fittings only.
- Failure to clean the system voids the warranty and can cause early heat exchanger failure.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation manual, p. 182 and 184. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.