Navien Boiler: No water at the hot water tap
No water at the hot water tap on a Navien boiler: Hot tap opened but no water comes out.
Applies to: Navien combination boiler, domestic hot water
Common causes of no water at the hot water tap
- Shut-off valve on the hot or cold pipe is closed
- Cold water filter is clogged
- Unit is frozen
- Cross-plumbing between cold and hot lines
- Error code flashing on the remote controller
How to fix no water at the hot water tap: step by step
- Open the shut-off valves on the hot and cold pipes.
- Clean the cold water filter.
- Check the remote controller for a flashing error code and look it up in the error code guide.
- Check whether the unit is frozen.
- Check for cross-plumbing between the cold and hot water lines.
- Confirm the tap is open enough to draw at least 0.5 GPM through the unit.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien User's Operation Manual, p. 40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.