Navien Boiler: Recirculation with a DHW return line installed

Updated · by Aurora Star Tech Inc.

Recirculation with a DHW return line installed on a Navien boiler: External recirculation can only be connected to and controlled by NPE-A2 water heaters.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 cascade with DHW recirculation return

How to fix recirculation with a dhw return line installed: step by step

  1. Connect the DHW return line to the required number of NPE-A2 water heaters.
  2. Set each unconnected NPE-A2 water heater to Internal Recirculation Mode.
  3. Set the NCB700 to Combi Pre-heat Mode.
  4. Set each recirculation-connected NPE-A2 using its 2-way valve and front panel DIP switches (see NPE-A2 manual).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien NCB700 installation and operation manual, p. 85. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.