Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code E031: Burner overheat (Boiler)

Updated · by Aurora Star Tech Inc.

Navien error code E031 on a boiler means: Burner overheat. It is also called Navien diagnostic code E031.

High severityBoilerNavien NFB-H

Homeowner? What Navien code E031 means for you

Call a technician Your boiler is reporting: Burner overheat. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code E031 mean?

NFB-H only. The burner temperature protection opened. Manual action: check the burner temperature fuse.

Applies to: Navien NFB-H fire-tube condensing boilers (NFB-175H/200H)

Common causes of Navien code E031

  • Burner temperature fuse / high limit open
  • Combustion problem overheating the burner area (blocked vent or heat exchanger, wrong orifice or CO2)
  • Loose connector on the burner limit
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code E031

NFB-175HNFB-200H

Other Navien Boiler codes

CodeMeaning
E003Ignition failure
E004False flame detected
E012Flame loss
E016Heat exchanger overheat (check flow / system filters)
E020Abnormal Gas Control Valve
E030Exhaust overheat
E046Heat exchanger thermistor fault
E047Exhaust thermistor fault
E060Dual venturi fault
E109Fan motor fault
E110Exhaust blockage
E123Abnormal Fan Motor Blower

All Navien Boiler error codes →

Navien code E031: homeowner questions

What does Navien code E031 mean?

Burner overheat. NFB-H only. The burner temperature protection opened. Manual action: check the burner temperature fuse.

Is it safe to keep using my boiler with code E031?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code E031 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code E031 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code E031 near me?

Aurora Star Tech Inc. repairs Navien boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Navien NFB-H Installation Manual, 11.7 Understanding Error Codes, p.116. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair