Navien Error Code E218: Heating return temperature sensor (Boiler)

Updated · by Aurora Star Tech Inc.

Navien error code E218 on a boiler means: Heating return temperature sensor. It is also called Navien diagnostic code E218.

Medium severityBoilerNavien NHB-H · Navien NFB-H

Homeowner? What Navien code E218 means for you

Check, then call Your boiler is reporting: Heating return temperature sensor. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code E218 mean?

Return water sensor fault. Manual action: check the thermistor connector.

Applies to: Navien NHB-H (NHB-055H/080H/110H/150H) and NFB-H fire-tube (NFB-175H/200H) condensing boilers

Common causes of Navien code E218

  • Loose or damaged return thermistor connector
  • Failed sensor
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models that use code E218

NFB-175HNFB-200HNHB-055HNHB-080HNHB-110HNHB-150H

Other Navien Boiler codes

CodeMeaning
E046Heat exchanger thermistor fault
E047Exhaust thermistor fault
E060Dual venturi fault
E109Fan motor fault
E110Exhaust blockage
E205Heating supply temperature sensor
E278External system supply sensor not detected
E279External system return sensor not detected
E291Return temperature higher than supply
E302Low water pressure
E352High water pressure
E353Water pressure sensor fault

All Navien Boiler error codes →

Navien code E218: homeowner questions

What does Navien code E218 mean?

Heating return temperature sensor. Return water sensor fault. Manual action: check the thermistor connector.

Is it safe to keep using my boiler with code E218?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Navien code E218 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code E218 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code E218 near me?

Aurora Star Tech Inc. repairs Navien boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Navien NHB-H Installation and Operation Manual, 11.14 Understanding Error Codes, p.119; Navien NFB-H Installation Manual, 11.7 Understanding Error Codes, p.116; NHB-H User's Information Manual (V1.0 Apr 2024), 5.2, p.24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.