Navien Boiler: Checking vent connections with the Vent Installation Detector (VID)
Checking vent connections with the Vent Installation Detector (VID) on a Navien boiler: The VID helps detect vent pipe separation at the collar, but it does not detect every leak or blockage.
Applies to: Direct vent connections at the boiler collar
Common causes of checking vent connections with the vent installation detector (vid)
- Vent pipe pushed out of the collar
- Leak or disconnect elsewhere in the vent run
- Blockage of the vent
How to fix checking vent connections with the vent installation detector (vid): step by step
- Insert the vent pipe into the VID to a depth of 2-3/4 in (70 mm); the VID should detect the pipe at this depth.
- Inspect all vent pipe connections periodically.
- Do not rely on the VID alone to find all vent movement or leaks.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation manual, p. 64. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.