Navien Boiler: Gas supply sizing and piping
Gas supply sizing and piping on a Navien boiler: Gas meter capacity must cover all connected appliances. The boiler should be the first appliance on the gas line.
Applies to: NFB-301C/399C
How to fix gas supply sizing and piping: step by step
- Confirm the gas meter capacity exceeds the total connected load (boiler plus furnace plus other appliances). Example in manual: 425 CFH meter for 195 + 58.8 + 63.7 CFH loads.
- Use 3/4 in rigid pipe sized per the Installation & Operation Manual tables.
- Do not use 3/4 in corrugated connectors or tubing, as they can cause noise.
- Leak test the appliance and gas connection before operation.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NFB-C quick installation guide, p. 1-2. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.