Navien Boiler: Understanding the Vent Installation Detector (VID)
Understanding the Vent Installation Detector (VID) on a Navien boiler: The VID only confirms the pipe is inserted at least 2-3/4 in into the collar. It is not a gas leak or CO detector and will not catch joints that come apart further along the vent run.
Applies to: NCB700 series
Common causes of understanding the vent installation detector (vid)
- Joints separating further along the vent run
- Blocked vent
- Sensor failure or switch sticking
How to fix understanding the vent installation detector (vid): step by step
- Inspect vent joints regularly because the VID will not detect separated joints or leaks.
- Use a CO detector as required by local code.
- Do not rely on the VID to catch vent movement after installation.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation and operation manual, p. 62-64. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.