Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Boiler: Space heating does not work while DHW is running

Updated · by Aurora Star Tech Inc.

Space heating does not work while DHW is running on a Navien boiler: The heating side stays off while the unit is heating domestic hot water.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Navien combination boiler, space heating

Common causes of space heating does not work while dhw is running

  • Normal 3 minute standby when switching from DHW to heating
  • Pre-heating mode places the heating side on standby
  • Restricted filter on the heating side

How to fix space heating does not work while dhw is running: step by step

  1. Wait about 3 minutes for the switch from DHW to heating to complete.
  2. Check whether the pre-heating icon is blinking on the remote controller.
  3. Clean the filters that belong to the heating side.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien User's Operation Manual, p. 41. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.