Navien Boiler: Space heating does not work while DHW is running
Space heating does not work while DHW is running on a Navien boiler: The heating side stays off while the unit is heating domestic hot water.
Applies to: Navien combination boiler, space heating
Common causes of space heating does not work while dhw is running
- Normal 3 minute standby when switching from DHW to heating
- Pre-heating mode places the heating side on standby
- Restricted filter on the heating side
How to fix space heating does not work while dhw is running: step by step
- Wait about 3 minutes for the switch from DHW to heating to complete.
- Check whether the pre-heating icon is blinking on the remote controller.
- Clean the filters that belong to the heating side.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien User's Operation Manual, p. 41. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.