Navien Boiler: Vent termination location checks
Vent termination location checks on a Navien boiler: Terminations must be placed clear of snow, public paths and openings.
Applies to: NCB700 series
How to fix vent termination location checks: step by step
- Keep the termination at least 12 in (305 mm) above the highest expected snow line, or higher if code requires.
- Protect the termination from snow blockage where snow accumulates.
- Keep the termination away from public walkways, soffit vents and crawl space vents.
- Do not store flammable or hazardous items near the termination.
- Elbows at the termination end are allowed if vent length, elbow count and clearances are within limits.
If the unit shows an error code, look it up: Navien Boiler codes
More commissioning tips for boiler
Source: Navien NCB700 installation and operation manual, p. 62. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.