Navien Boiler: Heating loop flow direction and accessory placement

Updated · by Aurora Star Tech Inc.

Heating loop flow direction and accessory placement on a Navien boiler: Water must flow through the manifold in one direction, and accessories go on the heating supply side.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB-H and NFC Series boiler with primary manifold

How to fix heating loop flow direction and accessory placement: step by step

  1. Route water from right to left: heating return enters from the right side of the manifold.
  2. Heating supply exits from the left side of the manifold.
  3. Install any required accessories such as an air separator with expansion tank, pump and check valve on the heating supply side, as shown in the manual's piping figure.
  4. Service and drain ports are on the service valves; use them as needed for flushing and filling.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien NCB-H, NFC Series Primary Manifold installation instructions, p. 2. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.