Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Error Code E593: Abnormal panel key (Boiler)

Updated · by Aurora Star Tech Inc.

Navien error code E593 on a boiler means: Abnormal panel key. It is also called Navien diagnostic code E593.

High severityBoilerNCB700

Homeowner? What Navien code E593 means for you

Call a technician Your boiler is reporting: Abnormal panel key. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code E593 mean?

The front panel key is faulty.

Applies to: NCB700 condensing combi-boiler

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Navien Boiler codes

CodeMeaning
E439No Dom. Water Flow Detected
E441Domestic hot water outlet 2 sensor fault
E445Abnormal mixing valve
E480DHW tank sensor not detected
E515PCB fault
E517DIP switch setting fault
E594EEPROM fault
E598RTC communication abnormality
E615Memory fault
E736Cascade communication fault
E740Outdoor sensor not detected
E761Pump aquastat not detected

All Navien Boiler error codes →

Navien code E593: homeowner questions

What does Navien code E593 mean?

Abnormal panel key. The front panel key is faulty.

Is it safe to keep using my boiler with code E593?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Navien code E593 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code E593 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code E593 near me?

Aurora Star Tech Inc. repairs Navien boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Navien NCB700 installation and operation manual, p. 137. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977