Navien Boiler: Install the Common Vent Collar Kit on the boiler

Updated · by Aurora Star Tech Inc.

Install the Common Vent Collar Kit on the boiler on a Navien boiler: The collar kit has a backdraft damper that blocks flue gas and cold air when the fan is off. It also has a maintenance port for checking the damper plate.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 with Navien Common Vent Collar Kit

How to fix install the common vent collar kit on the boiler: step by step

  1. Remove the screws from the exhaust vent adapter.
  2. Open the front cover.
  3. Detach the exhaust vent adapter from the top of the unit.
  4. Disconnect the Vent Installation Detector (VID) wiring from the harness.
  5. Connect the Common Vent Collar Kit to the exhaust duct of the boiler.
  6. Use the maintenance port to check the damper plate condition. Maintenance steps are in section 9.9, which is not on these pages.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien NCB700 Installation & Operation Manual, p. 96. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.