Recirculation without a DHW return line on a Navien boiler: Used when no recirculation return line is installed. HotButton mode cannot be used in this layout.
Applies to: NCB700 cascade without DHW return line
How to fix recirculation without a dhw return line: step by step
- Install a NaviCirc valve at the fixture furthest from the water heaters.
- Set the internal 2-way valve on the first NPE-A2 unit to the Ext position.
- Set the NCB700 to Combi Pre-heat Mode.
- Refer to the NaviCirc and NPE-A2 manuals for details.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation and operation manual, p. 86. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.