Navien Boiler: Cancel cascade communication settings
Cancel cascade communication settings on a Navien boiler: Use this to remove the cascade link so the water heaters go back to running on their own. Done from the main NCB700 panel.
Applies to: NCB700 main boiler with NPE sub water heaters
How to fix cancel cascade communication settings: step by step
- On the main NCB700 panel, press the Back button and the Menu button together and hold for 3 seconds.
- Select '4. Cascade Status and Set'.
- Select '2. Cascade System Removal'.
- Select 'YES'.
- The water heaters revert to independent operation.
- To reassign the main NCB700 boiler, repeat the cascade setup steps 1-5.
If the unit shows an error code, look it up: Navien Boiler codes
More reset & cancel tips for boiler
Source: Navien NCB700 Installation & Operation Manual, p. 88. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.