Navien Boiler: Valves, unions and check valves on heating circuit

Updated · by Aurora Star Tech Inc.

Valves, unions and check valves on heating circuit on a Navien boiler: Full-port ball valves are required. Check valves are recommended but must not sit between the close-spaced T connections and the expansion tank.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 space heating system

How to fix valves, unions and check valves on heating circuit: step by step

  1. Use full-port ball valves on the heating circuit
  2. Install check valves to prevent reverse flow during off-cycle pumping
  3. Do not install check valves, motorized valves or other shutoffs between the close T connections and the expansion tank, except for service
  4. Use unions to make service easier
  5. Tighten service valves carefully to avoid damaging them
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien NCB700 installation and operation manual, p. 187. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.