Navien Boiler: Draining the combination boiler
Draining the combination boiler on a Navien boiler: Have a bucket ready to catch water. The manual's figure shows the drain points, and the text reads some drain fittings as "coke" (likely cock or valve).
Applies to: CH combination boiler
How to fix draining the combination boiler: step by step
- Turn off power to the unit.
- Close the gas valve.
- Close the water supply valve on the unit inlet. If there is no valve, shut off the supply at the water meter.
- Open the pump drain on the pump and let the water drain.
- Open the pump drain at the hot outlet side, open the drain valves inside the unit, open the drain valve at the pump, and remove the filter from the cold inlet side.
- When fully drained, refit the pump drain plug and inlet filter and close the drain fittings inside the unit.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien CH User's Operation Manual, p. 33. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.