Flexible polypropylene or stainless vent installation on a Navien boiler: Flexible vent pipe is only allowed in a vertical run through the roof with indirect venting. Horizontal terminations are not allowed.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NCB700 flexible vent installs

How to fix flexible polypropylene or stainless vent installation: step by step

  1. Route all flexible vent pipe vertically through the roof. No horizontal terminations.
  2. Use proper adapters and supports to finish the install.
  3. Connect 2 in Innoflue Flex pipe to the exhaust with a 2 in snap-fit coupler or Innoflue single wall residential vent pipe.
  4. Make sure every joint is tightly sealed after installation.
  5. Use the flexible vent only for indirect venting.
  6. Check the flexible vent maximum length in the table for the model and vent diameter.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Boiler codes

Source: Navien NCB700 installation and operation manual, p. 76-77. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.