Navien Boiler: External recirculation with NaviCirc
External recirculation with NaviCirc on a Navien boiler: DHW recirculation loop using a NaviCirc valve on the faucet furthest from the boiler and a recirculation pump.
Applies to: NCB700 DHW recirculation
How to fix external recirculation with navicirc: step by step
- Select the Intelligent or Weekly option in the external recirculation DHW menu for best performance.
- To use aquastat control, install an aquastat on the DHW line and connect it to terminal CNC6 on the PCB.
- Install the NaviCirc recirculation valve on the faucet furthest from the boiler.
- Use a recommended recirculation pump (see the pump setting table on this page).
- Keep the recirculation pipe within the maximum length table.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation and operation manual, p. 35. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.