Navien Boiler: Vent installation detector limits
Vent installation detector limits on a Navien boiler: The vent installation detector only checks that the pipe is inserted to 70 mm in the exhaust collar. It does not detect leaks, pipe separation past the collar, blocked vents, vent movement, or a worn or stuck switch. Do not rely on it as a carbon monoxide alarm or safety switch. Inspect all vent joints regularly.
Applies to: NCB700 vent installation detector
How to fix vent installation detector limits: step by step
- Inspect all vent joints at regular intervals.
- Do not rely on the detector to find leaks, separated joints or blockages.
- Use a carbon monoxide detector as a separate safeguard.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation and operation manual, p. 235-237. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.