Navien Boiler: Zone valve system piping (primary/secondary)
Zone valve system piping (primary/secondary) on a Navien boiler: Piping layout for a multi-zone system using zone valves, with an air separator, expansion tank, pressure reducing valve and backflow preventer.
Applies to: NCB700 zone valve systems
How to fix zone valve system piping (primary/secondary): step by step
- Install a NaviClean filter in the system return to remove debris.
- Use a pump with an integral check valve, or fit a check valve at the pump outlet.
- Make up water connections per the 'Filling the Water System' section (p. 110) and follow local codes.
- Wire the zone valves per the zone valve wiring diagram (p. 44).
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NCB700 installation and operation manual, p. 32. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.