Navien Boiler: Cleaning the DHW cold water inlet filter
Cleaning the DHW cold water inlet filter on a Navien boiler: Clean the domestic hot water cold inlet filter if flow is poor. Have a bucket ready for draining water.
Applies to: CH combination boiler
How to fix cleaning the dhw cold water inlet filter: step by step
- Turn off power to the unit.
- Close the water supply valve on the unit inlet.
- Twist and remove the DHW cold water inlet filter.
- Rinse the filter under a faucet and scrub with a brush if needed.
- Refit the filter, open the supply valve slowly, and check for leaks.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien CH User's Operation Manual, p. 35. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.