Navien Boiler: Mounting the wall bracket and boiler
Mounting the wall bracket and boiler on a Navien boiler: Wall mount the boiler using the bracket from the L box. Use the fastener that suits the wall type. Do not mount on drywall without reinforcement.
Applies to: NFB-301C/399C
How to fix mounting the wall bracket and boiler: step by step
- Remove the wall bracket from the L box.
- Mount the anti-vibration rubber pad with its arrow pointing up.
- Wood stud wall: fasten the bracket with the lag bolts provided.
- Concrete wall: drill a 3/8 in diameter hole 3-1/2 in deep, insert the anchor and fasten with the anchor bolts provided.
- Metal stud wall: fasten with field-supplied toggle bolts rated for 100 lb each.
- Unfasten the 4 front cover latches (2 top, 2 bottom) to remove the cover before mounting the boiler.
If the unit shows an error code, look it up: Navien Boiler codes
Source: Navien NFB-C quick installation guide, p. 1. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.