Navien Error Code E773: Wrong gas type detected (Boiler)

Updated · by Aurora Star Tech Inc.

Navien error code E773 on a boiler means: Wrong gas type detected. It is also called Navien diagnostic code E773.

Medium severityBoilerNCB700

Homeowner? What Navien code E773 means for you

Check, then call Your boiler is reporting: Wrong gas type detected. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Navien error code E773 mean?

Warning shown when the boiler detects that the gas type it sees differs from the gas type set during installation. The check does not catch every bad gas connection, so the DIP switch setting must be verified before use. It can take some time to detect a mismatch, depending on gas flow and exhaust temperature. The code can also appear with the correct gas type set, because of normal measurement tolerances.

Applies to: NCB700 condensing combi-boiler

Common causes of Navien code E773

  • Gas type set on DIP switch 1 does not match the gas supply connected to the boiler
  • Gas type set during installation differs from the gas actually connected
  • Normal measurement tolerance in the unit, with the correct setting
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Navien Boiler codes

CodeMeaning
E598RTC communication abnormality
E615Memory fault
E736Cascade communication fault
E740Outdoor sensor not detected
E761Pump aquastat not detected
E762Vent pipe not fully inserted (VID)
E777Low water cutoff activated
E782Front panel communication fault
E784Zone controller communication fault
E786Improper front panel detected
E788Incorrect gas type setting
Elapsed Time After InstallEMS Data counter 1

All Navien Boiler error codes →

Navien code E773: homeowner questions

What does Navien code E773 mean?

Wrong gas type detected. Warning shown when the boiler detects that the gas type it sees differs from the gas type set during installation. The check does not catch every bad gas connection, so the DIP switch setting must be verified before use. It can take some…

Is it safe to keep using my boiler with code E773?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Navien code E773 myself?

You can try one reset (power off for 30 seconds, then on). If Navien code E773 comes back, the cause is still there and a licensed technician should check it.

Who can fix Navien code E773 near me?

Aurora Star Tech Inc. repairs Navien boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Navien NCB700 installation and operation manual, p. 62. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.