Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code EC72: Lack phase failure of outdoor DC fan motor (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EC72 on a heat pump means: Lack phase failure of outdoor DC fan motor. It is also called Viessmann diagnostic code EC72.

High severityHeat PumpVitocal 100-S · DLCURA

Homeowner? What Viessmann code EC72 means for you

Call a technician Your heat pump is reporting: Lack phase failure of outdoor DC fan motor. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EC72 mean?

The outdoor DC fan motor has a phase loss.

Applies to: Outdoor unit sizes 18K to 60K

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code EC72

Show all 22 models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other Viessmann Heat Pump codes

CodeMeaning
EC55Open or short circuit of temperature sensor (outdoor)
EC 56Evaporator coil outlet temperature sensor T2B open or shorted
EC56Open or short circuit of temperature sensor (outdoor)
EC57Refrigerant pipe temperature sensor error
EC71Overcurrent failure of outdoor DC fan motor
EC 72Missing phase failure of outdoor DC fan motor
EC73Zero-speed failure of outdoor DC fan motor
EH(xx)Indoor unit error code EH(xx)
EH 0bCommunication error between display board and main board
EH 0EWater-level alarm malfunction
EH0EWater-level alarm malfunction
EH00EEPROM parameter error

All Viessmann Heat Pump error codes →

Viessmann code EC72: homeowner questions

What does Viessmann code EC72 mean?

Lack phase failure of outdoor DC fan motor. The outdoor DC fan motor has a phase loss.

Is it safe to keep using my heat pump with code EC72?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code EC72 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EC72 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EC72 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCURA installation instructions, p. 20. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977