Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code EC50: Outdoor temperature sensor error (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EC50 on a heat pump means: Outdoor temperature sensor error. It is also called Viessmann diagnostic code EC50.

Low severityHeat PumpVitocal 100-S · DLCURA

Homeowner? What Viessmann code EC50 means for you

Usually minor Your heat pump is reporting: Outdoor temperature sensor error. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EC50 mean?

The outdoor temperature sensor is reporting a fault.

Applies to: Outdoor unit sizes 18K to 60K

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code EC50

Show all 22 models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other Viessmann Heat Pump codes

CodeMeaning
E910 - E912Reserved
EC(xx)Indoor unit error code EC(xx)
EC 0dOutdoor unit malfunction
EC 07Outdoor fan speed outside normal range
EC07Outdoor fan speed outside normal range
EC5CHigh pressure sensor failure
EC 51Outdoor unit EEPROM parameter error
EC51Outdoor EEPROM parameter error or compressor driven chip EEPROM parameter error
EC 52Condenser coil temperature sensor T3 open or shorted
EC52Open or short circuit of temperature sensor (outdoor)
EC 53Outdoor room temperature sensor T4 open or shorted
EC53Outdoor temperature sensor open or short circuit (T3, T4, TP, T2B, TH)

All Viessmann Heat Pump error codes →

Viessmann code EC50: homeowner questions

What does Viessmann code EC50 mean?

Outdoor temperature sensor error. The outdoor temperature sensor is reporting a fault.

Is it safe to keep using my heat pump with code EC50?

Usually yes. Code EC50 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code EC50 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EC50 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EC50 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCURA installation instructions, p. 20. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977