Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code PC 0L: Low ambient temperature protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code PC 0L on a heat pump means: Low ambient temperature protection. It is also called Viessmann diagnostic code PC 0L.

Low severityHeat PumpVitocal IND-O

Homeowner? What Viessmann code PC 0L means for you

Usually minor Your heat pump is reporting: Low ambient temperature protection. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PC 0L mean?

Operation lamp flashes 4 times, timer lamp flashing. In HEATING mode, if outdoor temperature stays below -13°F (-25°C) for 1 hour the unit shows PC 0L. It reverts to operation when outdoor temperature is above -7.6°F (-22°C) for 10 minutes and the compressor has stopped for one hour, or when outdoor temperature is above 23°F (-5°C) for 10 minutes.

Applies to: DLFSOAH09XAK, DLFSOAH18XAK

Common causes of Viessmann code PC 0L

  • Outdoor temperature below -13°F (-25°C) for 1 hour in HEATING mode
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
P5Indoor units mode conflict (multi-outdoor match)
PC(xx)Indoor unit error code PC(xx)
PC 0AHigh temperature protection of condenser
PC0AHigh temperature protection of condenser
PC 0FPFC module protection
PC0FPFC module protection
PC0LLow temperature protection of outdoor unit
PC 00IPM malfunction or IGBT over-strong current protection
PC00IPM malfunction or IGBT over-strong current protection
PC 01Over-voltage or low-voltage protection
PC01Overvoltage or low voltage protection
PC 02Compressor top temperature or IPM high temperature protection

All Viessmann Heat Pump error codes →

Viessmann code PC 0L: homeowner questions

What does Viessmann code PC 0L mean?

Low ambient temperature protection. Operation lamp flashes 4 times, timer lamp flashing. In HEATING mode, if outdoor temperature stays below -13°F (-25°C) for 1 hour the unit shows PC 0L. It reverts to operation when outdoor temperature is above -7.6°F (-22°C) for 10…

Is it safe to keep using my heat pump with code PC 0L?

Usually yes. Code PC 0L is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code PC 0L myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PC 0L comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PC 0L near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSOAH service manual, PDF p. 15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.