Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code HOP: High over pressure (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code HOP on a heat pump means: High over pressure. It is also called Viessmann diagnostic code HOP.

High severityHeat PumpVitocal 100-WA

Homeowner? What Viessmann code HOP means for you

Call a technician Your heat pump is reporting: High over pressure. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code HOP mean?

High pressure condition is active at this time.

Applies to: Vitocal 100-WA display

Common causes of Viessmann code HOP

  • Too little water flow in cool cycle
  • Clogged air filter in heat cycle
  • Air restriction in heat cycle

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code HOP

AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056

Other Viessmann Heat Pump codes

CodeMeaning
FH 07Communication fault between indoor unit and auto-lifting panel
FL 09Indoor and outdoor unit mismatch
FrEFreeze protection active
GASA2L gas leak
Heat Pump ModuleHeat pump error (outdoor unit)
HICompressor high speed
HP Inlet Temp.Outdoor unit inlet temperature sensor error
HP Low PressureOutdoor unit low refrigerant pressure
HP Outlet Temp.Outdoor unit outlet temperature sensor error
IDU PumpIndoor unit circulation pump error
Inlet Temp.Return temperature sensor error
LC 06IPM module high temperature protection

All Viessmann Heat Pump error codes →

Viessmann code HOP: homeowner questions

What does Viessmann code HOP mean?

High over pressure. High pressure condition is active at this time.

Is it safe to keep using my heat pump with code HOP?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code HOP myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code HOP comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code HOP near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 48. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977