Viessmann Error Code E515: Outlet temp too low protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code E515 on a heat pump means: Outlet temp too low protection. It is also called Viessmann diagnostic code E515.

Medium severityHeat PumpVitocal 100-AW

Homeowner? What Viessmann code E515 means for you

Check, then call Your heat pump is reporting: Outlet temp too low protection. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E515 mean?

Outlet water temperature is too low, triggering protection.

Applies to: Vitocal 100-AW AM2V outdoor unit

Common causes of Viessmann code E515

  • Insufficient water flow
  • Improper selection
  • Terminal not opened
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code E515

0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078

Other Viessmann Heat Pump codes

CodeMeaning
E114Room temp failure
E312Anti-freeze protection, 3 times
E510EVI outlet temp failure
E511Discharge temp failure
E513System 1 pressure sensor failure
E514Low ambient temp failure
E611Fan 1 failure
E612Fan 2 failure
E613Communication failure (main board with fan motor module board)
E614Reserved
E615Communication failure (main board with fan motor 2 module board)
E710AC input over current shutdown

All Viessmann Heat Pump error codes →

Viessmann code E515: homeowner questions

What does Viessmann code E515 mean?

Outlet temp too low protection. Outlet water temperature is too low, triggering protection.

Is it safe to keep using my heat pump with code E515?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code E515 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code E515 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code E515 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann Vitocal 100-AW AM2V installation, service and operating instructions, p. 78. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.