Viessmann error code E51 on a heat pump means: Outlet water temp failure. It is also called Viessmann diagnostic code E51.

Medium severityHeat PumpVitocal 100-AW

Homeowner? What Viessmann code E51 means for you

Check, then call Your heat pump is reporting: Outlet water temp failure. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E51 mean?

Outlet temperature sensor circuit is open, shorted or the sensor is damaged.

Applies to: Vitocal 100-AW AM2V outdoor unit

Common causes of Viessmann code E51

  • Open circuit or short circuit of the outlet temperature sensor
  • Outlet temperature sensor damaged
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code E51

0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078

Other Viessmann Heat Pump codes

CodeMeaning
E39Electric heating protection, 3 times
E40Discharge over heat protection, 3 times
E42Inlet/outlet water temp difference exceeded, 3 times
E43Outlet water temp too low, 3 times
E44Outlet water over temperature protection, 3 times
E50Inlet water temp failure
E52Coil temp failure
E53Ambient temp failure
E54Suction temp failure
E55Anti-freeze temp failure
E56Coil outlet water temp sensor failure
E59EVI inlet temp failure

All Viessmann Heat Pump error codes →

Viessmann code E51: homeowner questions

What does Viessmann code E51 mean?

Outlet water temp failure. Outlet temperature sensor circuit is open, shorted or the sensor is damaged.

Is it safe to keep using my heat pump with code E51?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code E51 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code E51 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code E51 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann Vitocal 100-AW AM2V installation, service and operating instructions, p. 77. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977