Viessmann Error Code Cooling temp.: Cold buffer temperature sensor error (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code Cooling temp. on a heat pump means: Cold buffer temperature sensor error. It is also called Viessmann diagnostic code Cooling temp..

Medium severityHeat PumpVitocal 100-AW

Homeowner? What Viessmann code Cooling temp. means for you

Check, then call Your heat pump is reporting: Cold buffer temperature sensor error. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code Cooling temp. mean?

Cold buffer temperature sensor has a fault.

Applies to: Vitocal 100-AW AM2V controller

Common causes of Viessmann code Cooling temp.

  • Cold buffer temperature sensor error
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code Cooling temp.

0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078

Other Viessmann Heat Pump codes

CodeMeaning
341 MCEMCE error
341 MCE errorMCE error
A2LA2L sensor fault
Circuit Config. ErrorHeating circuit configuration error
CommunicationIndoor to outdoor unit communication error
CONCondensate level too high
Curves Config. ErrorHeating curve configuration error
DFDefrost display (normal)
DHW Tank Temp.DHW tank temperature sensor error
E(x)Indoor unit error code E(x)
E10Reserved
E11Reserved

All Viessmann Heat Pump error codes →

Viessmann code Cooling temp.: homeowner questions

What does Viessmann code Cooling temp. mean?

Cold buffer temperature sensor error. Cold buffer temperature sensor has a fault.

Is it safe to keep using my heat pump with code Cooling temp.?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code Cooling temp. myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code Cooling temp. comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code Cooling temp. near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 69. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.